Electrical installation
Power terminals
Connection to the DC bus (+U
G
, −U
G
)
4
92
EDKCSDE040 DE/EN/FR 4.0
Cable cross−section
Cable
length
(module /
module)
Wire end ferrule Cable
cross−section
Tightening torque Stripping length
Up to 20 m
Without wire end
ferrule
6 mm
2
(AWG 10)
1.2 ... 1.5 Nm
(10.6 ... 13.3 lb−in)
5 mm for screw
connection
10 mm for spring
connection
With insulated wire
end ferrule
> 20 m
Without wire end
ferrule
10 mm
2
(AWG 8)
With insulated wire
end ferrule
Use pin−end
connectors for
wiring!