Sommario

Pagina 1 - PLC Developer Studio

LManualGlobal Drive9300 Servo PLCGlobal DrivePLC Developer Studio

Pagina 2 - Important note:

9300 Servo PLCPreface and general information 1−4l9300 Servo PLC EN 5.01.2.2 Node numbersThe system blocks of the 9300 Servo PLC carry the following n

Pagina 3

2.15 SYSTEM_FLAGS (system flags, node number 151)9300 Servo PLCSystem blocks 2−86L9300 Servo PLC EN 5.02.15 SYSTEM_FLAGS (system flags, node number 15

Pagina 4

9300 Servo PLCSystem blocks2.15 SYSTEM_FLAGS (system flags, node number 151) 2−87L9300 Servo PLC EN 5.0SYSTEM_bTogCycleTaskThis system flag toggles wi

Pagina 5

2.15 SYSTEM_FLAGS (system flags, node number 151)9300 Servo PLCSystem blocks 2−88L9300 Servo PLC EN 5.0

Pagina 6

9300 Servo PLCAppendix3.1 PLC functionality 3−1L9300 Servo PLC EN 5.03 Appendix3.1 PLC functionalityField Number DescriptionInputs Digital1 Input for

Pagina 7

3.2 Extendability/networking9300 Servo PLCAppendix 3−2L9300 Servo PLC EN 5.03.2 Extendability/networking59 3971728889LECOM A/BlUVTSzZyYSH PRGpPaR2 P

Pagina 8

9300 Servo PLCAppendix3.3 Memories 3−3L9300 Servo PLC EN 5.03.3 MemoriesThe below table gives you an overview of the memories available:Memory Size In

Pagina 9

9300 Servo PLCAppendix 3−4L9300 Servo PLC EN 5.03.3.1 Retain memoryIn the retain memory the values of the retain variables are stored safe from power

Pagina 10 - 9300 Servo PLC

9300 Servo PLCAppendix 3−5L9300 Servo PLC EN 5.03.3.2 Persistent memoryIn the persistent memory 32 bytes of data can be stored safe from power failure

Pagina 11

9300 Servo PLCAppendix 3−6L9300 Servo PLC EN 5.03.3.3 Downloading dataIn DDS (as of version 2.0) it is possible to attach a file to your project whose

Pagina 12

9300 Servo PLCAppendix3.4 System POUs 3−7L9300 Servo PLC EN 5.03.4 System POUsSystem POUs are POUs of the "program" type which accept the fe

Pagina 13

9300 Servo PLCPreface and general information 1−5l9300 Servo PLC EN 5.01.2.3 Access via system variablesYou can use the system variables of a system b

Pagina 14 - High Word Low Word 031

3.5 System error messages9300 Servo PLCAppendix 3−8L9300 Servo PLC EN 5.03.5 System error messagesThe fault memory (C0168/x) stores the error messages

Pagina 15

9300 Servo PLCAppendix3.5 System error messages 3−9L9300 Servo PLC EN 5.03.5.1 Overview of system error messages, error sources and responsesSystem er

Pagina 16

3.5 System error messages9300 Servo PLCAppendix 3−10L9300 Servo PLC EN 5.0System error message Possible settings/response Lenze setting  setting pos

Pagina 17

9300 Servo PLCAppendix3.5 System error messages 3−11L9300 Servo PLC EN 5.0System error message Possible settings/response Lenze setting  setting pos

Pagina 18

3.5 System error messages9300 Servo PLCAppendix 3−12L9300 Servo PLC EN 5.03.5.2 Response and its effects on the driveResponse  EffectKeypad displayRD

Pagina 19

9300 Servo PLCAppendix 3−13L9300 Servo PLC EN 5.03.5.4 Causes and remediesFault messageDescription Cause RemedyNo. Display−−− −−− No fault − −0011 OC1

Pagina 20

9300 Servo PLCAppendix 3−14L9300 Servo PLC EN 5.0Fault message RemedyCauseDescriptionNo.RemedyCauseDescriptionDisplayx061 CE0 Automation interface (AI

Pagina 21

9300 Servo PLCAppendix 3−15L9300 Servo PLC EN 5.0Fault message RemedyCauseDescriptionNo.RemedyCauseDescriptionDisplayx082 Sd2 Resolver error at X7 Res

Pagina 22

9300 Servo PLCAppendix 3−16L9300 Servo PLC EN 5.0Fault message RemedyCauseDescriptionNo.RemedyCauseDescriptionDisplayx200 Nmax Maximum speed (C0596) h

Pagina 23

9300 Servo PLCAppendix 3−17L9300 Servo PLC EN 5.03.5.5 Fault analysis via the fault memoryThe fault memory of the PLC consists of 8 memory locations w

Pagina 24

9300 Servo PLCPreface and general information 1−6l9300 Servo PLC EN 5.01.2.5 Definition of inputs/outputsThe application program is connected with the

Pagina 25

9300 Servo PLCAppendix 3−18L9300 Servo PLC EN 5.0Fault resetThe current fault can be reset by a TRIP−RESET e.g. via C0043:Code LCDPossible settingsInf

Pagina 26

9300 Servo PLCAppendix 3−19L9300 Servo PLC EN 5.03.5.6 Fault analysis via the LED display of the PLCTwo LEDs at the front of the PLC indicate the cont

Pagina 27

3.6 Code table9300 Servo PLCAppendix 3−20L9300 Servo PLC EN 5.03.6 Code tableHow to read the code table:Column Abbreviation MeaningCode C016812…8Code

Pagina 28

9300 Servo PLCAppendix3.6 Code table 3−21L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0011 Nmax 3000 Maximum speedRef

Pagina 29

3.6 Code table9300 Servo PLCAppendix 3−22L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0030 DFOUT const 3 Constant for

Pagina 30

9300 Servo PLCAppendix3.6 Code table 3−23L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0061 Heatsink tempgHeatsink tem

Pagina 31 - AIF_wControl

3.6 Code table9300 Servo PLCAppendix 3−24L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCD[C0085] Mot Ls  Leakage inducta

Pagina 32

9300 Servo PLCAppendix3.6 Code table 3−25L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCD[C0086] Mot type Selection of t

Pagina 33 - AOUT1_nOut_a

3.6 Code table9300 Servo PLCAppendix 3−26L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCD[C0086] Mot type Lenze asynchron

Pagina 34

9300 Servo PLCAppendix3.6 Code table 3−27L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCD[C0086] Mot type Lenze inverter

Pagina 35

9300 Servo PLCPreface and general information 1−7l9300 Servo PLC EN 5.01.2.6 Linking of system blocks with DDSThe system blocks required must be expli

Pagina 36

3.6 Code table9300 Servo PLCAppendix 3−28L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCD[C0089] Mot frequency  Rated mo

Pagina 37

9300 Servo PLCAppendix3.6 Code table 3−29L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0108 FCODE (gain) Freely config

Pagina 38

3.6 Code table9300 Servo PLCAppendix 3−30L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0128 TAU motor 5,0 Thermal time

Pagina 39

9300 Servo PLCAppendix3.6 Code table 3−31L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0150 Status wordgStatus word DC

Pagina 40

3.6 Code table9300 Servo PLCAppendix 3−32L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0157 Stat. FreeBitgStatus word

Pagina 41

9300 Servo PLCAppendix3.6 Code table 3−33L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCD[C0172] 0V reduce 10 Threshold f

Pagina 42

3.6 Code table9300 Servo PLCAppendix 3−34L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0206 Produkt dategProduction da

Pagina 43

9300 Servo PLCAppendix3.6 Code table 3−35L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0355 CAN IdgSystem bus: PDO ide

Pagina 44

3.6 Code table9300 Servo PLCAppendix 3−36L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0361 Load IN/OUTgSystem bus: Bu

Pagina 45

9300 Servo PLCAppendix3.6 Code table 3−37L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0381 HeartProTime 0 System bus:

Pagina 46

9300 Servo PLCPreface and general information 1−8l9300 Servo PLC EN 5.01.2.7 Signal types and scalingsMost inputs and outputs of Lenze function blocks

Pagina 47

3.6 Code table9300 Servo PLCAppendix 3−38L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0427 DFIN function 0 Digital fr

Pagina 48

9300 Servo PLCAppendix3.6 Code table 3−39L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0470 FCODE 8bit Freely configur

Pagina 49

3.6 Code table9300 Servo PLCAppendix 3−40L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCD[C0490] Feedback pos 0 Feedback

Pagina 50

9300 Servo PLCAppendix3.6 Code table 3−41L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0517 User menu User menu with u

Pagina 51

3.6 Code table9300 Servo PLCAppendix 3−42L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0549 DFOUT_nOut_vgDigital frequ

Pagina 52

9300 Servo PLCAppendix3.6 Code table 3−43L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0586 MONIT SD2 0 Monitoring con

Pagina 53

3.6 Code table9300 Servo PLCAppendix 3−44L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0606 MONIT OC8 2 Configuration

Pagina 54

9300 Servo PLCAppendix3.6 Code table 3−45L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0863 DIS: INx dig xgSystem bus:

Pagina 55 - System blocks

3.6 Code table9300 Servo PLCAppendix 3−46L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0868 DIS: OUTx.WxgSystem bus: P

Pagina 56

9300 Servo PLCAppendix3.6 Code table 3−47L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC0907 DIS: digitalgMCTRL_MotorCo

Pagina 57

9300 Servo PLCSystem blocks 2−1L9300 Servo PLC EN 5.02 System blocksThe following sections inform about the system blocks of the basic unit.

Pagina 58

3.6 Code table9300 Servo PLCAppendix 3−48L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC1191 Char.: temp PTC: Temperatu

Pagina 59

9300 Servo PLCAppendix3.6 Code table 3−49L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC2120 AIF: Control 0 AIF−CAN: Co

Pagina 60

3.6 Code table9300 Servo PLCAppendix 3−50L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC2354 XCAN sel.addr AIF−CAN: Def

Pagina 61

9300 Servo PLCAppendix3.6 Code table 3−51L9300 Servo PLC EN 5.0Code InfoPossible settingsLCDCode InfoSelectionLenzeLCDC2375 XCAN Tx−Mode AIF−CAN: TX m

Pagina 62

9300 Servo PLCAppendix 3−52L9300 Servo PLC EN 5.03.6.1 Temporary codesCodes C2500 and C2501 are temporary codes, i.e. the data does not occupy any EE

Pagina 63

9300 Servo PLCAppendix 3−53L9300 Servo PLC EN 5.0ParametersCode Data type Access InfoSubcode Possible settings PresettingC0504 − R / W Activate/deacti

Pagina 64

9300 Servo PLCAppendix 3−54L9300 Servo PLC EN 5.0Auto−increment accessThe four data bytes are always read/written through "auto−increment access&

Pagina 65

9300 Servo PLCAppendix3.7 Attribute table 3−55L9300 Servo PLC EN 5.03.7 Attribute tableIf you want to create your own programs, you will need the info

Pagina 66

3.7 Attribute table9300 Servo PLCAppendix 3−56L9300 Servo PLC EN 5.0AccessDataIndexCodeConditionLCM−R/WDecimalpositionDLFormatDTDADShexdecCodeC0037 24

Pagina 67

9300 Servo PLCAppendix3.7 Attribute table 3−57L9300 Servo PLC EN 5.0AccessDataIndexCodeConditionLCM−R/WDecimalpositionDLFormatDTDADShexdecCodeC0142 24

Pagina 68

2.1 AIF1_IO_AutomationInterface (node number 41)9300 Servo PLCSystem blocks 2−2L9300 Servo PLC EN 5.02.1 AIF1_IO_AutomationInterface (node number 41)2

Pagina 69

3.7 Attribute table9300 Servo PLCAppendix 3−58L9300 Servo PLC EN 5.0AccessDataIndexCodeConditionLCM−R/WDecimalpositionDLFormatDTDADShexdecCodeC0416 24

Pagina 70

9300 Servo PLCAppendix3.7 Attribute table 3−59L9300 Servo PLC EN 5.0AccessDataIndexCodeConditionLCM−R/WDecimalpositionDLFormatDTDADShexdecCodeC0594 23

Pagina 71

3.7 Attribute table9300 Servo PLCAppendix 3−60L9300 Servo PLC EN 5.0AccessDataIndexCodeConditionLCM−R/WDecimalpositionDLFormatDTDADShexdecCodeC2352 22

Pagina 72 - MCTRL_dnActIncLastScan_p

9300 Servo PLCIndex4−1L9300 Servo PLC EN 5.04 IndexAAbsolute value encoder, monitoring , 2−79 Additional torque setpoint, 2−49 Addresses, absolute,

Pagina 73

9300 Servo PLCIndex4−2L9300 Servo PLC EN 5.0Encoder cable monitoring, 2−34 Error messages, 3−8 Causes and remedies, 3−13 causes and remedies, 3−13

Pagina 74

9300 Servo PLCIndex4−3L9300 Servo PLC EN 5.0Phase controller, 2−54 Quick stop (QSP), 2−55 Speed controller, 2−52 Speed setpoint limitation, 2−54 S

Pagina 75

9300 Servo PLCIndex4−4L9300 Servo PLC EN 5.0POUs, 3−7 Program organisation unit (POU), 1−6 QQuick stop (QSP), 2−23 , 2−55 RRAM, 3−3 RAM access,

Pagina 76 - 9300 Servo PLC EN 5.0

9300 Servo PLCIndex4−5L9300 Servo PLC EN 5.0SYSTEM_FLAGS, 2−86 SYSTEM_FLAGS (system flags)Inputs SYSTEM_FLAGS, 2−86 Outputs SYSTEM_FLAGS, 2−87 Syst

Pagina 77

9300 Servo PLCSystem blocks2.1 AIF1_IO_AutomationInterface (node number 41) 2−3L9300 Servo PLC EN 5.0System variablesVariable Data type Signal type Ad

Pagina 78

2.1 AIF1_IO_AutomationInterface (node number 41)9300 Servo PLCSystem blocks 2−4L9300 Servo PLC EN 5.0User dataThe received 8 bytes of user data are as

Pagina 79

9300 Servo PLCSystem blocks2.1 AIF1_IO_AutomationInterface (node number 41) 2−5L9300 Servo PLC EN 5.0 2.1.2 Outputs_AIF1This SB is used as an interfac

Pagina 80

This documentation applies to the following Lenze PLC devices:Type designation As from hardware version As from software version9300 Servo PLC EVS93XX

Pagina 81

2.1 AIF1_IO_AutomationInterface (node number 41)9300 Servo PLCSystem blocks 2−6L9300 Servo PLC EN 5.0System variablesVariable Data type Signal type Ad

Pagina 82 -  Fixed response OC6−TRIP

9300 Servo PLCSystem blocks2.2 AIF2_IO_AutomationInterface (node number 42) 2−7L9300 Servo PLC EN 5.02.2 AIF2_IO_AutomationInterface (node number 42)2

Pagina 83

2.2 AIF2_IO_AutomationInterface (node number 42)9300 Servo PLCSystem blocks 2−8L9300 Servo PLC EN 5.0System variablesVariable Data type Signal type Ad

Pagina 84

9300 Servo PLCSystem blocks2.2 AIF2_IO_AutomationInterface (node number 42) 2−9L9300 Servo PLC EN 5.0 2.2.2 Outputs_AIF2This SB is used as an interfac

Pagina 85

2.2 AIF2_IO_AutomationInterface (node number 42)9300 Servo PLCSystem blocks 2−10L9300 Servo PLC EN 5.0System variablesVariable Data type Signal type A

Pagina 86

9300 Servo PLCSystem blocks2.3 AIF3_IO_AutomationInterface (node number 43) 2−11L9300 Servo PLC EN 5.02.3 AIF3_IO_AutomationInterface (node number 43)

Pagina 87

2.3 AIF3_IO_AutomationInterface (node number 43)9300 Servo PLCSystem blocks 2−12L9300 Servo PLC EN 5.0System variablesVariable Data type Signal type A

Pagina 88

9300 Servo PLCSystem blocks2.3 AIF3_IO_AutomationInterface (node number 43) 2−13L9300 Servo PLC EN 5.0 2.3.2 Outputs_AIF3This SB is used as an interfa

Pagina 89

2.3 AIF3_IO_AutomationInterface (node number 43)9300 Servo PLCSystem blocks 2−14L9300 Servo PLC EN 5.0System variablesVariable Data type Signal type A

Pagina 90

9300 Servo PLCSystem blocks2.4 AIF_IO_Management (node number 161) 2−15L9300 Servo PLC EN 5.02.4 AIF_IO_Management (node number 161)2.4.1 Inputs_AIF_M

Pagina 91

9300 Servo PLCContentsiL 9300 Servo PLC EN 5.01 Preface and general information 1−1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 92

2.4 AIF_IO_Management (node number 161)9300 Servo PLCSystem blocks 2−16L9300 Servo PLC EN 5.0System variablesVariable Data type Signal type Address Di

Pagina 93

9300 Servo PLCSystem blocks2.4 AIF_IO_Management (node number 161) 2−17L9300 Servo PLC EN 5.0 2.4.2 Outputs_AIF_ManagementThis SB transfers commands a

Pagina 94

2.5 ANALOG1_IO (node number 11)9300 Servo PLCSystem blocks 2−18L9300 Servo PLC EN 5.02.5 ANALOG1_IO (node number 11)2.5.1 Inputs_ANALOG1 (analog input

Pagina 95

9300 Servo PLCSystem blocks2.5 ANALOG1_IO (node number 11) 2−19L9300 Servo PLC EN 5.0Terminal assignment Set via C0034 whether the input is to be use

Pagina 96

2.6 ANALOG2_IO (node number 12)9300 Servo PLCSystem blocks 2−20L9300 Servo PLC EN 5.02.6 ANALOG2_IO (node number 12)2.6.1 Inputs_ANALOG2 (analog input

Pagina 97

9300 Servo PLCSystem blocks2.7 DCTRL_DriveControl (node number 121) 2−21L9300 Servo PLC EN 5.02.7 DCTRL_DriveControl (node number 121)This SB controls

Pagina 98

2.7 DCTRL_DriveControl (node number 121)9300 Servo PLCSystem blocks 2−22L9300 Servo PLC EN 5.02.7.1 Inputs_DCTRLSystem variablesVariables Data type Si

Pagina 99

9300 Servo PLCSystem blocks2.7 DCTRL_DriveControl (node number 121) 2−23L9300 Servo PLC EN 5.02.7.3 Quick stop (QSP)The QSP function is used to stop t

Pagina 100

2.7 DCTRL_DriveControl (node number 121)9300 Servo PLCSystem blocks 2−24L9300 Servo PLC EN 5.02.7.5 Controller inhibit (CINH)This function sets "

Pagina 101

9300 Servo PLCSystem blocks2.7 DCTRL_DriveControl (node number 121) 2−25L9300 Servo PLC EN 5.02.7.7 Resetting TRIP (TRIP−RESET)This function resets an

Pagina 102

9300 Servo PLCContentsiiL9300 Servo PLC EN 5.02.7 DCTRL_DriveControl (node number 121) 2−21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 103

2.7 DCTRL_DriveControl (node number 121)9300 Servo PLCSystem blocks 2−26L9300 Servo PLC EN 5.0 With C0150 you can display the status word:Code LCDPos

Pagina 104

9300 Servo PLCSystem blocks2.7 DCTRL_DriveControl (node number 121) 2−27L9300 Servo PLC EN 5.02.7.9 Transfer of status/control word via AIFIf the cont

Pagina 105

2.8 DFIN_IO_DigitalFrequency (node number 21)9300 Servo PLCSystem blocks 2−28L9300 Servo PLC EN 5.02.8 DFIN_IO_DigitalFrequency (node number 21)2.8.1

Pagina 106

9300 Servo PLCSystem blocks2.8 DFIN_IO_DigitalFrequency (node number 21) 2−29L9300 Servo PLC EN 5.0Tip!The process image is newly created for every ta

Pagina 107

2.8 DFIN_IO_DigitalFrequency (node number 21)9300 Servo PLCSystem blocks 2−30L9300 Servo PLC EN 5.0Configuration of the digital frequency input signal

Pagina 108

9300 Servo PLCSystem blocks2.8 DFIN_IO_DigitalFrequency (node number 21) 2−31L9300 Servo PLC EN 5.0Transmission functionDFIN_nIn_v + f[Hz] @60Strichz

Pagina 109

2.8 DFIN_IO_DigitalFrequency (node number 21)9300 Servo PLCSystem blocks 2−32L9300 Servo PLC EN 5.02.8.1.1 Technical data for the connection of X91234

Pagina 110

9300 Servo PLCSystem blocks2.8 DFIN_IO_DigitalFrequency (node number 21) 2−33L9300 Servo PLC EN 5.02.8.1.2 Touch probe (TP)Process: The current phase

Pagina 111

2.8 DFIN_IO_DigitalFrequency (node number 21)9300 Servo PLCSystem blocks 2−34L9300 Servo PLC EN 5.0Functional sequence1. The TP is activated via a sig

Pagina 112

9300 Servo PLCSystem blocks2.9 DFOUT_IO_DigitalFrequency (node number 22) 2−35L9300 Servo PLC EN 5.02.9 DFOUT_IO_DigitalFrequency (node number 22)2.9.

Pagina 113

9300 Servo PLCContentsiiiL 9300 Servo PLC EN 5.03 Appendix 3−1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 114

2.9 DFOUT_IO_DigitalFrequency (node number 22)9300 Servo PLCSystem blocks 2−36L9300 Servo PLC EN 5.0Configuration of the digital frequency output sign

Pagina 115

9300 Servo PLCSystem blocks2.9 DFOUT_IO_DigitalFrequency (node number 22) 2−37L9300 Servo PLC EN 5.0Configuration of the encoder constant The encoder

Pagina 116

2.9 DFOUT_IO_DigitalFrequency (node number 22)9300 Servo PLCSystem blocks 2−38L9300 Servo PLC EN 5.0Digital frequency output X10Technical dataConnecti

Pagina 117

9300 Servo PLCSystem blocks2.10 DIGITAL_IO (node number 1) 2−39L9300 Servo PLC EN 5.02.10 DIGITAL_IO (node number 1)2.10.1 Inputs_DIGITAL (digital inp

Pagina 118

2.10 DIGITAL_IO (node number 1)9300 Servo PLCSystem blocks 2−40L9300 Servo PLC EN 5.0 2.10.2 Outputs_DIGITAL (digital outputs)This SB conditions the d

Pagina 119

9300 Servo PLCSystem blocks2.11 FCODE_FreeCode (node number 141) 2−41L9300 Servo PLC EN 5.02.11 FCODE_FreeCode (node number 141)At Lenze, controller p

Pagina 120

2.11 FCODE_FreeCode (node number 141)9300 Servo PLCSystem blocks 2−42L9300 Servo PLC EN 5.0System variablesVariable Data type Signal type Address Disp

Pagina 121

9300 Servo PLCSystem blocks2.11 FCODE_FreeCode (node number 141) 2−43L9300 Servo PLC EN 5.0Note!The free code C0470 is stored under the same memory ad

Pagina 122 -  Dependent on C0086

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−44L9300 Servo PLC EN 5.02.12 MCTRL_MotorControl (node number 131)This SB contai

Pagina 123

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−45L9300 Servo PLC EN 5.0The process image is created in the course of a fixed s

Pagina 124

9300 Servo PLCContentsivL9300 Servo PLC EN 5.0

Pagina 125 - Appendix

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−46L9300 Servo PLC EN 5.0Variable NoteDisplayFormatDisplayCodeAddressSignal type

Pagina 126

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−47L9300 Servo PLC EN 5.02.12.2 Outputs_MCTRLSystem variablesVariable Data type

Pagina 127 -  Dependent on the controller

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−48L9300 Servo PLC EN 5.02.12.3 Current controllerTip!Select a matching motor fr

Pagina 128

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−49L9300 Servo PLC EN 5.02.12.4 Torque setpoint / additional torque setpointMCTR

Pagina 129 -  Rated motor current

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−50L9300 Servo PLC EN 5.02.12.5 Torque limitationVia MCTRL_nLoMLim_a and MCTRL_n

Pagina 130

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−51L9300 Servo PLC EN 5.02.12.6 Maximum speedThe maximum speed (nmax) is set und

Pagina 131

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−52L9300 Servo PLC EN 5.02.12.7 Speed controllerThe speed controller is designed

Pagina 132

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−53L9300 Servo PLC EN 5.0Signal limitationIf the drive outputs the maximum torqu

Pagina 133

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−54L9300 Servo PLC EN 5.02.12.9 Speed setpoint limitationThe speed setpoint limi

Pagina 134

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−55L9300 Servo PLC EN 5.02.12.11 Quick stop (QSP)The QSP function is used to sto

Pagina 135

9300 Servo PLCPreface and general information 1−1l9300 Servo PLC EN 5.01 Preface and general information1.1 About this ManualThis Manual describes the

Pagina 136

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−56L9300 Servo PLC EN 5.02.12.12 Field weakeningAdjusting the field weakening ra

Pagina 137

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−57L9300 Servo PLC EN 5.02.12.14 Feedback systemsThe following codes can be used

Pagina 138

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−58L9300 Servo PLC EN 5.02.12.15 Touch probe (TP)Process: The current phase valu

Pagina 139

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−59L9300 Servo PLC EN 5.0Function sequence1. The TP is activated via a signal ch

Pagina 140

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−60L9300 Servo PLC EN 5.02.12.16 Manual adaptation of motor dataIf you use a mot

Pagina 141

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−61L9300 Servo PLC EN 5.0Code IMPORTANTPossible settingsLCDCode IMPORTANTSelecti

Pagina 142

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−62L9300 Servo PLC EN 5.02.12.17 MonitoringThe 9300 Servo PLC comprises two inde

Pagina 143

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−63L9300 Servo PLC EN 5.0The fault memory (C0168/x) stores the error messages wi

Pagina 144

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−64L9300 Servo PLC EN 5.0Overview of system error messages of the motor controlE

Pagina 145

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−65L9300 Servo PLC EN 5.0Response and effect on the driveResponse  EffectKeypad

Pagina 146

9300 Servo PLCPreface and general information 1−2l9300 Servo PLC EN 5.01.1.3 Pictographs in this ManualPictographsusedSignal wordsWarning of materiald

Pagina 147

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−66L9300 Servo PLC EN 5.02.12.17.1 OC1 − short−circuit monitoringThis monitoring

Pagina 148

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−67L9300 Servo PLC EN 5.02.12.17.3 OC5 − I x t overload monitoringErrorMonitorin

Pagina 149

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−68L9300 Servo PLC EN 5.02.12.17.4 OC6 − I2 x t overload monitoringThe I2 × t lo

Pagina 150

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−69L9300 Servo PLC EN 5.02.12.17.5 OU − overvoltage monitoringThis function moni

Pagina 151

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−70L9300 Servo PLC EN 5.0Braking torque deratingWithout a braking system being c

Pagina 152

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−71L9300 Servo PLC EN 5.02.12.17.6 LU − undervoltage monitoringThis function mon

Pagina 153

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−72L9300 Servo PLC EN 5.02.12.17.7 LP1 − monitoring of the motor phasesThis moni

Pagina 154

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−73L9300 Servo PLC EN 5.02.12.17.8 OH − heatsink temperature monitoring (fixed)T

Pagina 155

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−74L9300 Servo PLC EN 5.02.12.17.9 OH3 − motor temperature monitoring (fixed)Thi

Pagina 156

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−75L9300 Servo PLC EN 5.02.12.17.10 OH4 − heatsink temperature monitoring (adjus

Pagina 157

9300 Servo PLCPreface and general information 1−3l9300 Servo PLC EN 5.01.2 System block introductionFor a long time, Lenze has followed the principle

Pagina 158

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−76L9300 Servo PLC EN 5.02.12.17.11 OH7 − motor temperature monitoring (adjustab

Pagina 159

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−77L9300 Servo PLC EN 5.02.12.17.12 OH8 − motor temperature monitoring via T1, T

Pagina 160

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−78L9300 Servo PLC EN 5.02.12.17.13 Sd2 − resolver monitoring for open circuitTh

Pagina 161

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−79L9300 Servo PLC EN 5.02.12.17.14 Sd6 − motor temperature sensor monitoringThi

Pagina 162

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−80L9300 Servo PLC EN 5.02.12.17.16 Sd8 − sin/cos encoder monitoring during oper

Pagina 163

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−81L9300 Servo PLC EN 5.02.12.17.17 PL − monitoring of the rotor position adjust

Pagina 164

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−82L9300 Servo PLC EN 5.02.12.17.18 nErr − speed monitoring (speed out of tolera

Pagina 165

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−83L9300 Servo PLC EN 5.02.12.17.19 NMAX − speed monitoring (maximum speed excee

Pagina 166

2.13 MCTRL_AUX_HighResFeedback (node number 181)9300 Servo PLCSystem blocks 2−84L9300 Servo PLC EN 5.02.13 MCTRL_AUX_HighResFeedback (node number 181)

Pagina 167

9300 Servo PLCSystem blocks2.14 STATEBUS_IO (node number 51) 2−85L9300 Servo PLC EN 5.02.14 STATEBUS_IO (node number 51)The state bus is a bus system

Commenti su questo manuale