Lenze EVS9332xP Manuale Utente Pagina 134

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 334
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 133
Function library
Function blocks
3−106
l
EDSVS9332P−EXT DE 2.0
Function
ANDx−IN1 ANDx−IN2 ANDx−IN3 ANDx−OUT
0 0 0 0
1 0 0 0
0 1 0 0
1 1 0 0
0 0 1 0
1 0 1 0
0 1 1 0
1 1 1 1
The function corresponds to a series connection of normally−open contacts in a contactor control.
ANDx−IN1
ANDx−IN2
ANDx−IN3
ANDx−OUT
Fig. 3−55 AND function as a series connection of normally−open contacts
Tip!
If only two inputs are required, use the inputs ANDx−IN1 and ANDx−IN2. Assign the input ANDx−IN3
to the signal source FIXED1 via the configuration code.
Vedere la pagina 133
1 2 ... 129 130 131 132 133 134 135 136 137 138 139 ... 333 334