Lenze MC Series Drives Manuale Utente Pagina 11

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 35
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 10
7 RG-MCMOD
Drive Setup & Operation
Table 5: Control (Parameter #30)
MC1000 MC3000
Setting Description Setting Description
00 LOCAL (default) 00 LOCAL (default)
01 REMOTE 01 REMOTE
02 BOTH 02 SERIAL
03 KEYPAD
04 TB STRIP
05 KEYPAD 2
All control options are subject to the Parameter and Control Locking/Unlocking procedures.
4.4 Unlocking & Locking Controls
Registers #48 and #1 are used in Unlocking and Locking Controls.
A write to Register #48 (Unlock Controls) with a value of 0 will unlock controls. This enables the writing
of Register #1 – the Drive Control Register.
If Register #48 (Unlock Controls) is written with a value that is the Drive’s Programming Password, then
in addition to Register #1(Drive Control), writing to all other writeable registers is enabled (e.g.: register
#52 -- Preset Speed #1). The factory default password for MC series drives is 19.
Once Register #48 (Unlock Controls) has been written, Controls are unlocked until the Lock Security
flag (Bit 1 of Register#1) has been set or until a Watchdog Timeout occurs.
Writing to Register #1 (Drive Control) with bit 1 set will Lock both Controls and Parameters (prevents
writing to any register).
The serial drive control can only be unlocked when the drive is not in programming mode.
When LOCK is asserted, the drive drops out of SERIAL control and reverts back to the previous source
of control.
Even though drive might be locked, and thus parameters and control cannot be written, parameters
and status can always be read. Refer to section 4.7,
Monitoring Only Operation
.
4.5 Unlocking & Locking Programming Parameters only
Registers #49 and #1 are used in Unlocking and Locking Programming Parameters.
Writing to any writeable register other than #1 can be enabled by writing the Drive’s Programming
Password to Register #49 (Unlock Parameters). This would be done when Drive Control (start, forward/
reverse, keypad speed control, etc.) is not required.
The Factory Default password is 19.
Once Register #49 (Unlock Parameters) has been written, the writing of parameter registers is enabled
until Bit 1 of Register #1 has been set.