Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manuale Utente Pagina 464

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 679
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 463
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
464 Firmware 1.37 - 09/2006 L
DC-bus capacitor: Temperature > CXXXXX [0x00770004]
DC-bus capacitor: overtemperature [0x00770005]
Inside the device: Temperature > CXXXXX [0x00770006]
Inside the device: Overtemperature [0x00770007]
CPU: Temperature > C00126 [0x00770008]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked : Warning Information
Cause Remedy
Electrolytic capacitor temperature higher than warning
threshold.
Check control cabinet temperature.
Clean filter.
Clean controller.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Electrolytic capacitor temperature higher than limit
temperature (120 °C).
Check control cabinet temperature.
Clean filter.
Clean controller.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked : Warning Information
Cause Remedy
Inside temperature higher than warning threshold. Check control cabinet temperature.
Clean filter.
Clean controller.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Inside temperature higher than limit temperature (85
°C).
Check control cabinet temperature.
Clean filter.
Clean controller.
Response (Lenze setting printed in bold) Setting: C00589 (; Adjustable response)
: None System fault ; Fault Trouble Quick stop by trouble Warning locked ; Warning Information
Cause Remedy
CPU temperature higher than variable limit temperature
(C00126
).
Controller ambient temperature too high.
Dirty fan or ventilation slots.
Value set under C00126 is too low.
Check control cabinet temperature.
Clean filter.
Clean controller.
Set a higher value under C00126
.
Vedere la pagina 463
1 2 ... 459 460 461 462 463 464 465 466 467 468 469 ... 678 679

Commenti su questo manuale