EDS94AYFLF EN 3.2 - 10/2010 L 21
Digital frequency extension module | Parameter setting & configuration
Digital frequency output
Terminal assignment X10
3 Digital frequency output
The optionally available digital frequency extension module serves to extend the L-force
9400 Servo Drive by a digital frequency input and a digital frequency output.
The digital frequency output X10 serves to output encoder signals with TTL level
(0 ... 500 kHz).
3.1 Terminal assignment X10
Pin Signal
1B
2A
3A
4+5 V (±6%)
5GND
6Z
7Z
8Enable
9B