Lenze i700 Manuale Utente Pagina 175

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 338
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 174
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05 175
7 CiA402 device profile
7.4 Device control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4.1.4 Activate quick stop
From all states
Power section inhibited (pulse inhibit)
Power section enabled
This command serves to activate quick stop
when operation is enabled.
Irrespective of the setpoint specified, the
drive is brought to a standstill with the
deceleration set for quick stop (0x6085
or
0x6885
for axis B).
A changeover to the "Quick stop is active
"
device status takes place.
If the operation has not been enabled yet
(status "Ready to switch on
" or "Switched on"),
this command triggers a change to the "Switch
on disabled" device status.
Bit pattern for the "Quick stop" in the Controlword (0x6040 or 0x6840 for axis B):
Bits 15 - 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Fault reset Control bits depending on the operating mode Enable
operation
Activate quick
stop
Enable voltage Switch on
X0X X XX01X
Note!
During quick stop, the drive executes the setpoint generation and no longer follows the
setpoint defined by the controller!
If several drives execute a chained synchronous motion, the quick stop function has to
be coordinated by the Controller by means of a quick stop profile (master function). In
this case, quick stop cannot be activated via the control bit 6!
1
2
0
Ready to
switch on
Not ready to
switch on
Switched
on
Operation
enabled
Fault reaction
active
Fault
Switch-on
disabled
Quick stop
active
Power-on
Vedere la pagina 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 337 338

Commenti su questo manuale

Nessun commento