L DMS 4.0 EN - 07/2007 31
L-force Loader
Control via script files
Structure of the script file
Target system-dependent settings - [DEVICE...] sections
Every target system must have a [DEVICE???] section. The question marks must be replaced
by consecutive numbers (001
... NumberOfDevices).
r If you have defined the key NumberOfDevices=3 in the [COMMON] section, the
following three sections must be available:
[DEVICE001], [DEVICE002], [DEVICE003].
r The target systems are processed subsequently, starting with [DEVICE001].
The following settings can be made for every section:
Key Parameter
NodeAddress Designation of the bus server and address of the target system (see following
examples).
The address is displayed in the dialog area in the Busserver field.
Example 1 - communication via system bus
In the following example, the target system has the CAN node address "11".
Check also key "SDO"!
NodeAdress=Lenze OPC Systembus Server.11
Example 2 - communication via LECOM
In the following example, the target system has the LECOM node address "5".
NodeAdress=Lenze OPC Lecom Server.1-5
Example 3 - communication with L-force 9400 Servo Drives via diagnostic adapter
If only one
diagnostic adapter is connected to the PC, the default address "0" is to be
indicated:
NodeAdress=Lenze OPC Diagnostics Server.0
If several diagnostic adapters are connected to the PC, unambiguous addressing
requires the indication of the diagnostic adapter's serial number.
The serial number (S/N) is printed on the diagnostic adapter.
The serial number can also be displayed in the diagnostics configurator. For this
purpose, select the diagnostic adapter in the configurator and click Diagnostics
on the Common tab.
In the following example, the diagnostic adapter has the serial number
"00001628".
NodeAdress=Lenze OPC Diagnostics Server.1-1628
Example 4 - communication with 9400 Servo Drives via Ethernet NRT
In the following example, the OPC Ethernet server has the default address "1".
The IP address is specified with the "IP" key.
NodeAddress=Lenze OPC Ethernet Server.1
IP IP address
Only required for communication with 9400 Servo Drives via Ethernet NRT.
The dots of the IP address must be replaced by underline characters.
Example:
IP=172_31_201_38
SDO Parameter channel (1 or 2) for communication.
Only required for communication via system bus (CAN).
For a better performance, select the same parameter channel for all devices in the
script file.
If "0" is set, there is no division into channels and the entire node address range
is accepted.