Lenze Drive Server Bus server S7 getting started Manuale Utente Pagina 44

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 63
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 43
Busserv er S7
L
105Busserver S7 DE/EN 1.0
6.3.5 FC92 (FC Process Data, 2 words)
Function for process data access
The function FC92 can be used for both consistent and i nconsistent process da ta transfer.
Parameters Data type Possible values/meaning
EA_Address IN: INT I/O address of the process data channel
e. g. 1008
Enable IN: BOOL
TRUE Drive enabled
E
n
a
b
l
e
I
N
:
B
O
O
L
FALSE Drive inhibited
QSP IN: BOOL
TRUE Quick stop (QSP) active
Q
S
P
I
N
:
B
O
O
L
FALSE Quick stop (QSP) not active
Reset IN: BOOL FALSE äTRUE TRIP reset executed
Setpoint1 IN: INT Setpoint process value (AIF-IN:W1)
ControlWord IN: WORD Control word according to DRIVECOM specification
Bit0 ... Bit4 are hidden and cannot be written.
RDY OUT: BOOL
TRUE Drive is ready for operation
O
U
O
O
FALSE Drive is not ready for opera tion
TRIP OUT: BOOL
TRUE Drive signals TRIP
O
U
O
O
FALSE Drive does not signal TRIP
ActualValue1 OUT: INT Actual process value (AIF-OUT:W1)
StatusWord OUT: WORD Status word according to DRIVECOM specification
Show/Hide Bookmarks
Vedere la pagina 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 62 63

Commenti su questo manuale

Nessun commento