9 Parameter data transfer
9.2 Reading and writing parameters
74
Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.2.2 Writing parameters (SDO download)
1. The master sends "Initiate Domain Download Request".
2. The slave acknowledges the request with a positive response ("Initiate Domain Download
Response").
In the event of an error the slave responds with "Abort Domain Transfer".
Note!
In the case of jobs for the inverter, please make sure that you convert the code into an
index.
Indexing of the Lenze codes
( 69)