9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
104 L EDS94TA11010xxxx EN 1.2 - 03/2010
CiA402 Homing method 20
Processes:
Case 1: Axis has not yet activated reference switch:
1. Movement in positive direction with profile data set 1.
2. The following positive edge of reference switch sets reference (0x607C
).
3. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Case 2: Axis already stands on reference switch:
1. Movement in negative direction with profile data set 2.
2. Reversing with negative edge of reference switch.
3. The following positive edge of reference switch sets reference (0x607C
).
4. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").