EDS94TA10060xxxx EN 1.2 - 03/2010 L 75
9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Parameterisable function blocks
5.14.14 PosStarted
5.14.15 RestartPosTransition
Is an instance of Function
L_TbTransition Edge generation for resetting the "drive at the target" state
Parameter Possible settings Information
C04000 Trigger edge
0 Rising edge Lenze setting
1 Falling edge
2Both edges
C04001 0.001 s 60.000 Pulse duration
Initialisation: 0.001 s
Is an instance of Function
L_TbTransition Edge generation for restart of positioning
Parameter Possible settings Information
C04002 Trigger edge
0 Rising edge Lenze setting
1 Falling edge
2Both edges
C04003 0.001 s 60.000 Pulse duration
Initialisation: 0.005 s