Lenze PLC Designer PLC-Designer (R2-x) SoftMotion Manuale Utente Pagina 153

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 290
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 152
DMS 5.2 EN 03/2011 TD17 L 153
L-force | PLC Designer - SoftMotion
The SM_PLCopen.lib library
POUs for the synchronised motion control (multi-axis)
Outputs (VAR_OUT)
StartSync: BOOL (Default: FALSE)
The output is TRUE until the slave axis is being coupled in. As soon as the slave is coupled
in completely, StartSync becomes FALSE and InSync becomes TRUE.
InSync : BOOL (default: FALSE)
This output reports TRUE if the slave is coupled in.
Busy : BOOL (default: FALSE)
Indicates that the POU is not completed.
Active: BOOL (Default: FALSE)
Indicates that the function block controls the axis.
CommandAborted : BOOL (default: FALSE)
The motion that had started was interrupted by another function block acting on the same
axis (exception: MoveSuperImposed).
Error : BOOL (default: FALSE)
TRUE indicates an error in the function block.
ErrorID : SMC_Error (INT )
Error number
Vedere la pagina 152
1 2 ... 148 149 150 151 152 153 154 155 156 157 158 ... 289 290

Commenti su questo manuale

Nessun commento