Application example: Flying saw
Mapping the actual machine structure in the »PLC Designer«
154
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.2 Mapping the actual machine structure in the »PLC Designer«
13.2.1 Device structure: Adding master and slave
How to map the machine structure in the »PLC Designer«:
1. Right-click the controller and select the Add device command to add the "EtherCAT
Master":
2. Add the EtherCAT slaves below the EtherCAT Master:
Right-click the EtherCAT Master and execute the Add device command. Select the
desired devices from the selection list . Repeat the Add device command until all slaves
connected to the fieldbus are included in the device view.