Electrical installation
Wiring of the feedback system
Important notes
5
l
99
EDKVF9338 DE/EN/FR 4.0
5.7 Wiring of the feedback system
5.7.1 Important notes
ƒ An incremental encoder can be connected to input X8 or input X9:
– Incremental encoders with TTL level are connected to X8.
– Incremental encoders with HTL level are connected to X9.
ƒ The incremental encoder signal can be output for slave drives at the digital
frequency output X10.
) Note!
ƒ We recommend to use Lenze system cables for wiring.
ƒ For self−made cables only use cables with shielded cores twisted in pairs.