Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014 51
Extending sample projects - adding devices
Creating a control configuration - EtherCAT bus system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8 Extending sample projects - adding devices
This chapter informs you on how to extend the control configuration manually.
Lenze provide ready-made sample projects in which the control configuration has already been
created. More information can be found in the following section: Working with the sample
projects ( 23)
Proceed as described below to extend an existing sample project individually. Please note that
the communication settings have to be adapted for each individual node.
8.1 Creating a control configuration - EtherCAT bus system
How to create the control configuration in the »PLC Designer«:
1. Open the context menu of the target system and execute the command Append device
in order to extend the control configuration with "EtherCAT Master".
Note!
Before creating an EtherCAT configuration in »PLC Designer«, ensure that the following
conditions have been met:
The sequence of EtherCAT slaves in the device tree must correspond to the physical
arrangement of the EtherCAT topology.
In order that the system works properly, end terminals must not be used when setting
up the system configuration in the device tree.
Select the cycle times according to the technical data, from 1 ... 10 ms.