Lenze ETC Motion Control Manuale Utente Pagina 44

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 428
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 43
Getting started
Parameterising drives via machine constants
Testing the drives in inching mode
2
2.8
2.8.7
l
44
EDSTCXN EN 2.0
2.8.7 Testing the drives in inching mode
After the machine constants have been adapted, the drives must be tested
in inching mode. Check whether the configured drives behave according to
the specifications.
1. In the ETC MMI window, press <F9> (setup).
The MMI window opens in the "Setup" operating mode.
2. Press <F2> (Manual travel).
3. In the submenu, press <F1> (Modal travel).
An individual drive is selected. The selected drive is indicated by the
setpoint with a green background.
ETCN011
4. In the submenu, alternately press <S3> (Travel +) and <S4>(Travel −).
In inching mode, the selected drive rotates in positive or negative
direction.
5. To change the speed of the drive, press <S6> (Override +) or <S7>
(Override −).
6. To select the next axis for traversing, press <S5> (axis).
The green setpoint display switches.
Vedere la pagina 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 427 428

Commenti su questo manuale

ama 11 Jan 2025 | 19:35:39

rasha