Lenze ETC Motion Control Manuale Utente Pagina 83

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 428
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 82
Getting started
Updating the firmware of the ETCHx in the "Standalone" operating mode
Calling the boot monitor in the control system
2
2.16
2.16.1
l
83
EDSTCXN EN 2.0
2.16 Updating the firmware of the ETCHx in the "Standalone" operating mode
) Note!
The steps described in this chapter only apply to the ETCHx
variant (DIN rail variant); they are not required for the ETCPx
variant (PCI card).
2.16.1 Calling the boot monitor in the control system
Initial state: The communication between PC and ETCHx has been
established and the monitor interface activated ( 21)
1. In the terminal program, enter the command reboot.
2. During the running reboot process, press and hold the <Shift> + <!>
keys.
ETCM012
When the prompt ">" appears, the input in the boot monitor of the
control system is active. On the control system, the LEDs 1 ... 6 flash
circulatingly.
) Note!
When the firmware is running, the control system can also be
reset by switching the control system on/off or by pressing the
reset key.
Vedere la pagina 82
1 2 ... 78 79 80 81 82 83 84 85 86 87 88 ... 427 428

Commenti su questo manuale

ama 11 Jan 2025 | 19:35:39

rasha