Lenze PLC Designer V2.x Manuale Utente Pagina 200

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 336
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 199
PLC Designer V2.x| Lenze Application Samples
Working with the sample projects
9300 - "LAS_40_INTF_Can_93_EP" sample project
200 L 1.3 EN - 07/2012
Further information on the FB can be found in the following section: Structure of
S93_DriveControl_93xxEP - actuation to the 9300 EP controller ( 280)
Area visualises the FB for reading out the errors from the controller.
Further information on the FB can be found in the following section:
L_S93_ReadErrorCode - read out error status
( 282)
Mode/profile Meaning
Homing
byProfileNumber = 2 Start homing
Positioning
byProfileNumber = 4 or 5
byProfileNumber = 7
Start positioning
Direct positioning with the set position "iSetPos". The positioning range is
limited to +/- 32767.
Via the "xErrorSet" button, an external error is triggered.
Via the "xErrorReset" button, the error can be reset.
Speed
byProfileNumber = 6 Start speed operation
The controller approaches the setpoint "rNset" in a speed-controlled
manner.
Vedere la pagina 199
1 2 ... 195 196 197 198 199 200 201 202 203 204 205 ... 335 336

Commenti su questo manuale

Nessun commento