9 "CAN on board" system bus
9.2 Possible settings by DIP switch
296
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.2 Possible settings by DIP switch
The DIP switches on the front of the memory serve to set the baud rate and the node address.
[9-1] DIP switch
9.2.1 Setting the node address
The node address can be set via code C00350 or with the DIP switches 1 to 64.
• The labelling on the housing corresponds to the values of the individual DIP switches for
determining the node address.
• Valid address range: 1 … 127
Example: Setting of the node address 23
Tip!
The node address resulting from the setting of the DIP switches at the last mains switching
is displayed in C00349/1
.
Baud
CAN Address
O
N
cdba
64
32
16 8
421
Note!
• The addresses of the nodes must differ from each other.
•All
twelve DIP switches = OFF (Lenze setting):
• At switching on, the settings under code C00350
(node address) and C00351 (baud
rate) will become active.
• Switch the voltage supply of the basic device off and then on again to activate altered
settings.
DIP switch 64 32 16 8 4 2 1
Switch position OFF OFF ON OFF ON ON ON
Value 0 0
16 0 4 2 1
Node address = Sum of the values = 16 + 4 + 2 + 1 = 23