14 Parameter reference
14.2 Parameter list | C02531
852
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02531
C02532
C02533
C02534
C02535
Parameter | Name:
C02531 | Gearbox factors (decimal)
Data type: UNSIGNED_32
Index: 22044
d
= 561C
h
Note: In subcode 3 the effective gearbox factor resulting form the motor and the load is displayed if a separate
position encoder is configured and the position control is activated (C02570
="2"). For a different encoder
configuration (without a separate position encoder) the value "1" is shown in subcode 3.
Drive interface
Display range (min. value | unit | max. value)
0.000 2147483.647
Subcodes Info
C02531/1 Motor gearbox factor (dec.)
C02531/2 Pos. enc. gearbox factor (dec.)
C02531/3 Effective gearbox factor (dec.)
Read access Write access CINH PLC STOP No transfer Scaling factor: 1000
Parameter | Name:
C02532 | Resolution of a unit
Data type: UNSIGNED_32
Index: 22043
d
= 561B
h
Drive interface
Display range (min. value | unit | max. value)
0.0000 Incr./unit 214748.3647
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02533 | Time unit
Data type: UNSIGNED_32
Index: 22042
d
= 561A
h
Drive interface
Selection list (read only)
2 s
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02534 | Used time unit
Data type: VISIBLE_STRING
Index: 22041
d
= 5619
h
Display of the time unit as a character string
Drive interface
Read access Write access CINH PLC STOP No transfer Scaling factor: 1 Character length: 8
Parameter | Name:
C02535 | Used unit
Data type: VISIBLE_STRING
Index: 22040
d
= 5618
h
Display of the unit set in C02525 and C02526 as a character string
Drive interface
Read access Write access CINH PLC STOP No transfer Scaling factor: 1 Character length: 8
Vedere la pagina 851
1 2 ... 847 848 849 850 851 852 853 854 855 856 857 ... 953 954

Commenti su questo manuale

Nessun commento

Bb-electronics Hardware Benutzerhandbücher

Beginnend mit R

Klicken Sie auf den Alphabet unten, um zur vollständigen Liste der Modelle zu gelangen, die mit diesem Buchstaben beginnen

Modelle Dokumententyp
RS-232/422/485 Serial Card CE 3PXCC4A
Bedienungsanleitung   B&B Electronics RS-232/422/485 Serial Card CE 3PXCC4A User Manual, 47 Seiten
RS-232 Digital I/O Module 232SDD16
Bedienungsanleitung   B&B Electronics RS-232 Digital I/O Module 232SDD16 User Manual, 27 Seiten
RS-232 Digital Relay I/O 232DRIO
Bedienungsanleitung   B&B Electronics RS-232 Digital Relay I/O 232DRIO User Manual, 28 Seiten
RS-232 to Ethernet Converter ES1A
Bedienungsanleitung   B&B Electronics RS-232 to Ethernet Converter ES1A User Manual, 54 Seiten
RS-485 Digital I/O Module 485SDD16
Bedienungsanleitung   B&B Electronics RS-485 Digital I/O Module 485SDD16 User Manual, 28 Seiten