Lenze 9400 Manuale Utente Pagina 64

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 954
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 63
4 Drive interface
4.2 Device commands
64
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.19 Reset quick stop
The C00002 = "46: Reset quick stop" device command is used to exit an active quick stop again.
Related device commands
Activate quick stop
( 63)
Note!
Please note that the quick stop is only exited if all sources for quick stop are reset!
C00159
displays a bit code of active sources/causes for the quick stop.
This device command has no status display in C00003
, i.e. the display remains
unchanged showing the previous device command status.