Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 85
4 Drive interface
4.2 Device commands
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.37 Activate parameter set 1 ... 4
In addition to the start parameters, up to four further parameter sets can be stored in the memory
module for each application. Like this you can for instance define different controller settings for an
application, which are then simply activated via device command, if required.
The following device commands are used to archive the current parameter settings of the controller
for the active application in the memory module as parameter set 1 ... 4:
C00002
= "301: Archive parameter set 1"
C00002
= "302: Archive parameter set 2"
C00002
= "303: Archive parameter set 3"
C00002
= "304: Archive parameter set 4"
[4-21] Example: "Archive parameter set 1" function
Previously archived parameter settings will be overwritten with the current parameter settings!
* In this example, application 1 is the active application
PS 4
PS 3
PS 2
Application 2
PS 1
PS
PS 4
PS 3
PS 2
Memory module MM
PS
9400
PS
RAM
Firmware Application 1*Application 1*
PS
PS 1
Vedere la pagina 84