Lenze ยท Servo-Inverter 9400 HighLine ยท Reference manual ยท DMS 10.0 EN ยท 11/2013 ยท TD05/06 693
13 Diagnostics & fault analysis
13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
CAN module (MXI2): Lifeguarding error [0x00ad0020]
CAN module (MXI2): Faulty NMT slave configuration [0x00ad0021]
CAN module (MXI2): Faulty emergency configuration [0x00ae0000]
Module ID (decimal) Error ID (decimal)
173: CAN module in MXI2: CAN-NMT handler 32
Response (Lenze setting printed in bold) Setting: C14614 (๏ƒพ Adjustable response)
๏ƒฝ None ๏‚จ System fault ๏ƒพ Fault ๏ƒพ Trouble ๏ƒพ Quick stop by trouble ๏ƒพ Warning locked ๏ƒพ Warning ๏ƒพ Information
Cause Remedy
CANopen communication module in MXI2: Cyclic node
monitoring
โ€ข Slave response: Maximum time between two node
guarding telegrams (remote transmission request
telegram) from the master has been exceeded.
Select a different Lifeguarding monitoring time or switch
off monitoring.
Module ID (decimal) Error ID (decimal)
173: CAN module in MXI2: CAN-NMT handler 33
Response (Lenze setting printed in bold)
๏‚จ None ๏‚จ System fault ๏‚จ Fault ๏‚จ Trouble ๏‚จ Quick stop by trouble ๏ƒฝ Warning locked ๏‚จ Warning ๏‚จ Information
Cause Remedy
CANopen communication module in MXI2: A
configuration error has occurred in the network
management of the CAN slave.
โ€ข Faulty download of an Engineer or PLC Designer
project
โ€ข Invalid CAN settings according to DS301V402 in the
Engineer or PLC Designer.
โ€ข Incorrect parameterisation of node guarding or
heartbeat.
โ€ข Repeat download
โ€ข Correct CAN settings in the project and regenerate
project.
Module ID (decimal) Error ID (decimal)
174: CAN module in MXI2: CAN emergency handler 0
Response (Lenze setting printed in bold)
๏‚จ None ๏‚จ System fault ๏‚จ Fault ๏‚จ Trouble ๏‚จ Quick stop by trouble ๏ƒฝ Warning locked ๏‚จ Warning ๏‚จ Information
Cause Remedy
CANopen communication module in MXI2: CAN
emergency configuration is faulty.
โ€ข Faulty download of an Engineer or PLC Designer
project
โ€ข Invalid CAN emergency settings according to
DS301V402 in the Engineer or PLC Designer.
โ€ข Repeat download
โ€ข Correct CAN settings in the project and regenerate
project.